S NO
|
Specification
| |
1
|
Make
| COSMOSTAT |
2
|
Technology
|
Servo controlled
|
3
|
Type
|
Three phase, Indoor, unbalanced,
|
4
|
Cooling
|
Oil / Air
|
5
|
Testing
|
As per BIS 9815: Part 1
|
6
|
Input voltage
|
200V-500V phase to phase as per requirement
|
7
|
Output voltage
|
415V +/- 1% (Adjustable)
|
8
|
Frequency
|
50 Hz
|
9
|
Rate of correction
|
8 V/-60 Vsec. phase to phase
|
10
|
Metering
|
Digital microprocessor based cards
|
11
|
Efficiency
|
Not less than 98 %
|
12
|
Wave form Distortion
|
Nil
|
13
|
Response time
|
Less than 10 mili second
|
14
|
Break down strength
|
2500 Ac for 2 minute
|
15
|
Insulation Resistance (IR)
|
More than 100 Mega ohms at 500V DC
|
16
|
Capacity
|
6 KVA to 1500 KVA
|
Protections:-
| ||
1
|
Over load/short circuit Protection
|
Optional (Price Quoted Separately)
|
High / low voltage cut off
|
Optional (Price Quoted Separately)
| |
Single phase preventer
|
Optional (Price Quoted Separately)
| |
By-pass arrangement
|
Optional (Price Quoted Separately)
| |
As per BIS 9815:part1:1994 Technical Specifications:-
| ||
SL NO
|
Parameter
|
Observation
|
1
|
Winding
|
Pure electrolyte copper
|
2
|
Manufactured with Both dimmer state and transformer
|
Dimmerstate 3 nos, transformer 3 nos and servo motor 3 nos each in unit
|
3
|
Size of stabilizer L X B X H (in inches)
|
Declared in advance at time quotation
|
4
|
Minimum size of dimmer state unit
|
Declared in advance at time quotation
|
5
|
Oil capacity
|
Declared in advance at time quotation
|
Electrical Substation Now days the electrical power demand is increasing very rapidly. For fulfilling these huge power demands the modern time requires creation of bigger and bigger power generating stations. These power generating stations may be hydro-electric, thermal or atomic. Depending upon the availability of resources these stations are constructed different places. These places may not be nearer to load centers where the actual consumption of power takes place. So it is necessary to transmit these huge power blocks from generating station to their load centers. Long and high voltage transmission networks are needed for this purpose. Power is generated comparatively in low voltage level. It is economical to transmit power at high voltage level. Distribution of electrical power is done at lower voltage levels as specified by consumers. For maintaining these voltage levels and for providing greater stability a number of transformation and switching stations have to be created in