Install Exact Rating of Servo stabilizer



Normally it is observed that, customer ask for extra rating of servo stabilizer to meet the future demand of load. Two three point to be considered before going for the extra higher capacity of servo stabilizer:

1. When you are going to increase the load (machines)

2. Present Load measured or just guess work.

3. Input Voltage Range

4. Weather the transformer at the input can take the extra load or no

If above points have been discussed with the technical staff, then consider the following points:

You should be aware of that any transformer has losses, suppose we go for 50 KVA Extra capacity of servo stabilizer, it will cost us huge amount of energy thus money. 

For more information please call Akil Siddiqui @ +91-9818596585 or mail us cosmostat@gmail.com

Comments

Post a Comment

Popular posts from this blog

Electrical Power Substation - Type of Electrical substation

Electrical Substation Now days the electrical power demand is increasing very rapidly. For fulfilling these huge power demands the modern time requires creation of bigger and bigger power generating stations. These power generating stations may be hydro-electric, thermal or atomic. Depending upon the availability of resources these stations are constructed different places. These places may not be nearer to load centers where the actual consumption of power takes place. So it is necessary to transmit these huge power blocks from generating station to their load centers. Long and high voltage transmission networks are needed for this purpose. Power is generated comparatively in low voltage level. It is economical to transmit power at high voltage level. Distribution of electrical power is done at lower voltage levels as specified by consumers. For maintaining these voltage levels and for providing greater stability a number of transformation and switching stations have to be created in ...

What Is Energy Efficiency Level 2 Transformer ?

High-efficiency transformers make financial benefits for the society. Other than diminished greenhouse gas emanations, they progress reliability and deliver possibly longer benefit life by bringing down temperature rises through energy-efficiency advancements. India has, by presently, received the universal IEC standards as well as presented star naming for chosen categories of transformers. Most power losses happen within the transformer core made up of magnetic steel or within the electrical coils or windings of either aluminum or copper. Copper diminishes load loss, since it could be a more proficient conductor. The significant Indian standard for distribution transformers (DTs) IS:1180/1989 has been changed within the year 2014 as IS:1180 (Part1)/2014 by Bureau of Indian Standard (BIS) subsequently superseding IS:1180 (Portion 1 and 2)/1989 both for fixed and non-sealed sort. This standard advance prescribes numerous reviewing with respect to vitality effectiveness, i.e. three ...

Ring Main Unit (RMU)

  Ring Main Unit,   RMU   is a compact, enclosed and sealed type of Switchgear used for medium voltage power distribution. It is a complete Switchgear in itself. A complete Switchgear means, assembly of required switching devices, protection device as well as metering device. RMU of different voltage (mostly 12 kV and 24 kV) and current ratings are available.  Indoor as well as outdoor types of Ring Main Units are available. Ring Main Unit comprises of one incomer feeder and one or more outgoing feeder. The incomer feeder is either Vacuum Circuit Breaker or SF 6  Circuit Breaker with associated Disconnect Switch and Earth Switch. This incomer feeder is given with the provision of bushing protruding from the enclosure of RMU for supply cable connection. A typical Ring Main Unit is shown in figure below. Outgoing feeder comprises of Load Break Switches with associated Disconnect Switch and Earth Switch. Provision for cable connection is provided in outgoing f...