Usually the power distribution voltage is not 230V, 400V, the low three-phase power is more than 200 volts, the high one is 400 volts, and the single-phase power is the same. The high and low voltages sometimes differ greatly, so before we buy the voltage stabilizer, we need to have a measurement on the electrical sample used. The voltage stabilizer manufacturers will set the minimum and  maximum voltage value of the user of the voltage stabilizer according to the electrical sample, and then obtain the fluctuation range value of it. Then according to the obtained the output voltage fluctuation value indicates the most suitable voltage stabilization range of the voltage stabilizer, and generally, when choosing the voltage stabilization, the voltage stabilization range of the voltage stabilization range is wider than the actual range. Regardless of the regulator produced by the regulator manufacturer, no matter what type of regulator, there will be some voltage stabilization range. The so-called voltage stabilization range is based on the normal voltage value as a starting point and can accept the highest voltage. The ratio of the voltage to the lowest voltage. If it exceeds this range, it is overvoltage, and if it is below this range, it is undervoltage. So what should I do if the output voltage of the regulator is too high or too low? Can we adjust ourselves?

 Generally, the automatic voltage regulators (avr) are adjusted and tested before they leave the factory, and customers are not allowed to adjust without permission. There is a voltage fine-tuning device on the motherboard of each regulator. However, the range of each adjustment is 5V. T


herefore, the special situation of overvoltage or under voltage in the voltage stabilizer can be solved by adjusting the voltage stabilizer itself. Let me explain the precautions of the adjustment method.

 Regulation requirements

1. Disconnect the connection line with the equipment before adjustment, and then connect it after adjustment to avoid damage to the electrical products of the equipment.

2. Personal adjustment requires technical support from the regulator manufacturer to determine the location of the device for fine-tuning the voltage.

3. The regulator must be an electrician or a person with common sense to avoid potential safety hazards of accidental electric shock.

4. It is recommended to operate by 2 people, one for fine-tuning, and one for observing the voltmeter for more precise operation.

5. Prepare to unpack tools and fine-tuning tools (size cross screwdriver).

 Adjustment method

First of all, please disconnect the power supply and connect the equipment line, and disassemble the regulator case. Generally, the regulator shell is fixed by screws, and then remove all the screws on both sides to remove the case. Remove the regulator shell After opening, the internal circuits, copper coils, carbon brushes, etc. will appear. Don't touch anything at this time. Carefully find the circuit board of the servo voltage stabilizer, and then find the adjustment screw for the fine-tuning voltage module according to the shape characteristics provided by the technician. At this time, we can power on the voltage stabilizer first, then find a smaller Phillips screwdriver and place it on the adjustable module, and then fine-tune the voltage clockwise or counter clockwise while observing the voltmeter on the voltage stabilizer until it reaches what we want The required voltage is enough, and finally all the lines are connected and the drive is completed.

for more information please call Akil Siddiqui @ +91-9818596585 or mail us cosmostat@gmail.com 


Comments

  1. Here we come up with new machinery plant named Alaquainc, which specializes in designing and manufacturing a broad range of different crystallizer systems designs to fulfill diverse client requirements. To learn more about Alaqua Inc please visit on the website www.alaquainc.com

    ReplyDelete

Post a Comment

Popular posts from this blog

Electrical Power Substation - Type of Electrical substation

Electrical Substation Now days the electrical power demand is increasing very rapidly. For fulfilling these huge power demands the modern time requires creation of bigger and bigger power generating stations. These power generating stations may be hydro-electric, thermal or atomic. Depending upon the availability of resources these stations are constructed different places. These places may not be nearer to load centers where the actual consumption of power takes place. So it is necessary to transmit these huge power blocks from generating station to their load centers. Long and high voltage transmission networks are needed for this purpose. Power is generated comparatively in low voltage level. It is economical to transmit power at high voltage level. Distribution of electrical power is done at lower voltage levels as specified by consumers. For maintaining these voltage levels and for providing greater stability a number of transformation and switching stations have to be created in

What Is Energy Efficiency Level 2 Transformer ?

High-efficiency transformers make financial benefits for the society. Other than diminished greenhouse gas emanations, they progress reliability and deliver possibly longer benefit life by bringing down temperature rises through energy-efficiency advancements. India has, by presently, received the universal IEC standards as well as presented star naming for chosen categories of transformers. Most power losses happen within the transformer core made up of magnetic steel or within the electrical coils or windings of either aluminum or copper. Copper diminishes load loss, since it could be a more proficient conductor. The significant Indian standard for distribution transformers (DTs) IS:1180/1989 has been changed within the year 2014 as IS:1180 (Part1)/2014 by Bureau of Indian Standard (BIS) subsequently superseding IS:1180 (Portion 1 and 2)/1989 both for fixed and non-sealed sort. This standard advance prescribes numerous reviewing with respect to vitality effectiveness, i.e. three ener

Inner View Of 100 KVA Servo Stabilizer

Inner View Of 100 KVA 3 Phase Servo Stabilizer Make: COSMOSTAT Capacity : 100 KVA Input : 300 V - 470 V Output : 415 V Phase : 3Type: Unbalance Cooling : Oil Cooled Winding : 99.9% Pure Copper Termination : Copper For more information please call  Akil Siddiqui  @ +91-9818596585 or mail us  cosmostat@gmail.com Website:  www.servostabilizer.in Join us:  www.facebook.com/servostabilizer.in               www.twitter.com/digitalservo